Call Us Today! (919) 544-8887  [email protected]
This is a preview of the category card.
Metal Roof Panels & Wall Panels
Categories

Custom Metal Roof & Wall Panels

Metal roof panel forming machine
Made to Order for Your Project

Standing Seam Roofing & Architectural Wall Panels

K&M Sheet Metal manufactures metal roof and wall panels in a range of profiles, materials and sizes. Choose from mechanical lock, snap lock, nail strip, U-panel batten systems and flat-lock panels for residential, commercial and architectural projects.

Material options include copper, zinc, aluminum and steel, with finishes and thicknesses that vary by profile. We also review requests for curved or tapered panels and supply supporting clips, flashing, fasteners and sheet metal tools.

Compare Metal Roof Panel Systems

Standing seam describes panels with raised seams between adjacent pans. The way those seams close and attach to the building differs by system. Compare the connection, material and project requirements before choosing a profile.

Mechanical Lock

Clip-attached panels with seams folded closed during installation. Explore single- and double-lock configurations and custom curved-panel options.

Snap Lock

Clip-attached panels with interlocking seams that snap together. They avoid the separate mechanical seam-closing operation along the panel joints.

Nail Strip

Snap-together panels with a concealed fastening flange built into the panel edge. The attachment differs from a separate-clip snap-lock system.

Mechanical lock standing seam metal roof panel profile

Mechanical Lock Standing Seam Panels

K&M’s mechanical lock profile is available with 1-inch and 1.5-inch seam heights. Adjacent male and female edges engage and are folded with suitable seaming tools. A single lock uses the first seam-closing stage; a double lock adds a second fold. Specify the required seam configuration for the roof assembly.

The panels attach with concealed clips. Copper, zinc and other suitable metals can be considered according to the profile and project details. Curved and tapered mechanical lock panels are available for review by custom quote; provide the radius, dimensions and material requirements.

View Mechanical Lock Roofing Panels
Snap lock standing seam metal roof panel profile

Snap Lock Standing Seam Panels

Available in 1-inch and 1.5-inch seam heights, this system uses a snap-together joint and separate concealed clips. It can reduce seam-closing work compared with a mechanically seamed profile, while still requiring careful layout, flashing and attachment.

K&M’s standard snap-lock profile is intended for straight runs rather than curved roof surfaces. Clip selection and material suitability must match the panel system. Confirm the selected metal and thickness before ordering, especially for softer materials such as copper.

View Snap Lock Roofing Panels
Nail strip standing seam metal roof panel profile with integral fastening flange

Nail Strip Standing Seam Panels

K&M offers nail strip profiles with 1-inch and 1.5-inch seam heights. Fasteners pass through the concealed flange along the panel edge, and the adjoining panel snaps over the connection. Separate panel clips are not used in the same way as with a clip-attached system.

This profile can be considered for shorter runs, subject to the system requirements. Thermal movement still matters: panel length, fastening method and attachment details must allow the panel to perform as intended. Confirm material compatibility and permitted lengths for your project.

Ask About Nail Strip Panels
U-panel metal roof profile for a batten-seam assembly

U-Panels & Batten-Seam Roofing

K&M’s U-panel profile has upturned edges in 1-inch or 1.5-inch heights. Used with compatible heavy-duty batten cleats and a separate batten cap, it creates a raised batten-style joint between panels. This cleat-and-cap arrangement does not require a wood batten.

The U-panel described here is the architectural profile shown in the diagram. Match the panel, cleat and batten cap as an assembly, and confirm the material, support and project details before fabrication.

Discuss a Batten-Seam Project
Flat-lock metal panel profile for roof and wall applications

Flat-Lock Roof & Wall Panels

Flat-lock panels use folded edges to join smaller pieces into a repeating pattern. K&M can fabricate different shapes and sizes for architectural roofs, domes, turrets and wall cladding. Square, rectangular and diamond layouts create a different appearance from long standing-seam panels.

For K&M’s flat-roof flat-lock applications, the seams require soldering and a suitable solderable metal. Pre-tinning of edges is available. Painted aluminum and steel are options for appropriate wall applications, not substitutes for solderable metal in this flat-roof assembly.

On exterior walls, coordinate the panel joints, attachment, backing and drainage details. A decorative metal pattern alone does not establish a complete weather-resistant wall assembly.

View Flat-Lock Panels

Materials & Finishes for Roof and Wall Panels

Copper & Copper-Based Materials

Copper offers a natural finish that changes with weather exposure and can be soldered where the detailing calls for it. Copper, Freedom Gray and lead-coated copper options commonly include 16-ounce and 20-ounce sheet weights. Confirm availability and suitability for the selected profile.

Painted Aluminum & Steel

Kynar-finished aluminum and steel provide color choices for coordinating roofing, wall panels and trim. Aluminum thicknesses and steel gauges are different measurements; specify the actual metal, thickness and finish. Coastal exposure should be discussed before selecting a substrate and coating.

Zinc & Other Options

Zinc can be considered for compatible architectural roof and wall details, including flat-lock patterns. Galvalume Plus and other metals may also be available for selected systems. A material shown on a color chart is not automatically available for every panel.

Provide a finish manufacturer, color name or code, and thickness when coordinating panels with flashing. Screen colors are reference images; ask about physical samples before making a final selection.

Panel Coverage, Coil Width & Seam Allowances

Coil width is not finished coverage. Some of the flat metal becomes the raised seams or fastening flange. Use the finished coverage width to lay out the roof or wall and calculate panel quantities.

The following reference shows K&M’s listed forming allowances for these profiles. The allowance is metal used to form the edges, not simply discarded scrap. Confirm the finished dimensions on the selected drawing before ordering.

Reference forming allowances; dimensions are in inches.
Panel profileSeam heightWidth used in formingExample coverage from 20-inch stock
Mechanical lock1317
Mechanical lock1.5416
Snap lock1317
Snap lock1.5416
Nail strip1317
Nail strip1.5515
U-panel1218
U-panel1.5317

The examples subtract the listed allowance from 20-inch stock; they are not a statement that every width and material is stocked or suitable. Batten-seam layout also needs the joint spacing shown on its assembly drawing. Flat-lock panel coverage depends on the locks and layout in both directions.

Choosing Coil and Blank Sizes

Common starting widths include 18, 20 and 24 inches for copper-based materials, and 16, 18, 20 and 24 inches for selected aluminum and steel coils. Other widths depend on material supply and fabrication. For flat-lock work, selecting blank sizes that divide efficiently into the sheet can reduce offcuts; the finished face is smaller than the unformed blank.

Confirm the Roof or Wall Assembly Before Ordering

Roof Slope & Attachment

Minimum roof slope depends on the exact panel and seam configuration, not seam height alone. Confirm the applicable instructions for the selected system, including any requirements for sealants, end laps, deck support, clips and fasteners. Flat-lock soldered roofing still needs a coordinated drainage design.

For engineered projects, provide the specified test standards and assembly requirements. Ask K&M which UL or ASTM documentation is available for the particular panel, material, width and attachment arrangement.

Thermal Movement & Appearance

Metal panels expand and contract as temperature changes. Attachment details, panel length and transitions need to accommodate that movement, including on nail-strip systems.

Oil canning is visible waviness in the flat areas of a metal panel. Stiffening ribs or striations can help reduce its visibility, but cannot guarantee a perfectly flat appearance. Discuss panel width, thickness, surface options and appearance expectations before fabrication.

Plan the Trim and Accessories Together

A panel order is one part of the installation. Depending on the project, you may also need compatible clips and fasteners, underlayment, closures, eave trim, rake or gable trim, ridge caps, valleys, wall flashing and penetration details. Mechanical-lock and soldered systems also require the appropriate tools and supplies.

Ordering Custom Panel Lengths

The Mechanical Lock and Snap Lock online listings sell panels by the lineal foot, with a 100-lineal-foot minimum. Those listings specify lengths from 3 to 20 feet for shipping, or up to 40 feet for pickup at K&M. Confirm the limits for your selected profile and delivery arrangement; these figures do not apply automatically to every custom panel.

Provide a cut list showing how many panels you need at each length. For example, 10 panels at 12 feet plus 5 panels at 8 feet total 160 lineal feet. Lineal feet measure total panel length; they are not the same as square feet of installed coverage.

  • Profile: Panel type, seam height, seam configuration and finished coverage width.
  • Material: Metal, thickness, finish, color and any requested ribs or striations.
  • Dimensions: Quantities and lengths, plus drawings for curved, tapered or flat-lock work.
  • Application: Roof slope or wall location, substrate, attachment and project specifications.
  • Delivery: Pickup or shipping, destination ZIP code, unloading arrangements and requested schedule.

Long panels need suitable transport, support and handling. Confirm access and unloading arrangements before ordering, and allow separately for production and transit time.

Color and Material Options

Kynar® Aluminum & Galvalume Steel

Black kynar aluminum

Black

Matte black kynar steel

Matte Black
**24 Gauge Steel Only

Dark bronze kynar aluminum and galvalume

Dark Bronze

Medium bronze kynar aluminum and galvalume

Medium Bronze

Almond kynar aluminum and galvalume

Almond

Bone white kynar aluminum and galvalume

Bone White

Copper penny kynar aluminum and galvalume

Copper Penny

Charcoal kynar aluminum and galvalume

Charcoal

Special Order Colors

Special Order colors require a minimum 2000 sqf. purchase for coil. Most colors have a 1 sheet minimum per order. Extra freight charges apply.

Patina green kynar aluminum and galvalume

Patina Green

Teal kynar aluminum and galvalume

Teal

Hemlock green kynar aluminum and galvalume

Hemlock Green

Forest green kynar aluminum and galvalume

Forest Green

Hartford green kynar aluminum and galvalume

Hartford Green

Evergreen kynar aluminum and galvalume

Evergreen

Hunter green kynar aluminum and galvalume

Hunter Green

Arcadia green kynar aluminum and galvalume

Arcadia Green

Military blue steel kynar aluminum and galvalume

Military Blue

Berkshire blue kynar aluminum and galvalume

Berkshire Blue

Graphite kynar aluminum and galvalume

Graphite

Interstate blue kynar aluminum and galvalume

Interstate Blue

Slate blue kynar aluminum and galvalume

Slate Blue

Award blue kynar aluminum and galvalume

Award Blue

Burnished slate kynar aluminum and galvalume

Burnished Slate

Aged bronze kynar aluminum and galvalume

Aged Bronze

Mansard brown kynar aluminum and galvalume

Mansard Brown

Burgundy kynar aluminum and galvalume

Burgundy

Terra cotta kynar aluminum and galvalume

Terra Cotta

Cardinal red kynar aluminum and galvalume

Cardinal Red

Colonial red kynar aluminum and galvalume

Colonial Red

Midnight bronze kynar aluminum and galvalume

Midnight Bronze

Musket gray kynar aluminum and galvalume

Musket Gray

Sierra tan kynar aluminum and galvalume

Sierra Tan

Sandstone kynar aluminum and galvalume

Sandstone

Slate gray kynar aluminum and galvalume

Slate Gray

Cityscape kynar aluminum and galvalume

Cityscape

Granite

Stone white kynar aluminum and galvalume

Stone White

Anodic clear kynar aluminum and galvalume

Anodic Clear

Silversmith kynar aluminum and galvalume

Silversmith

Silver kynar aluminum and galvalume

Silver

Champagne kynar aluminum and galvalume

Champagne

Zinc colored kynar aluminum and galvalume

Zinc

Weathered zinc colored kynar aluminum and galvalume

Weathered Zinc

Aged copper colored kynar aluminum and galvalume

Aged Copper

Weathered steel kynar aluminum and galvalume

Weathered Steel

More Information

Kynar coated material is supplied by Petersen (Pac-Clad).
Colors are mostly available in 0.032″ and 0.040″ aluminum as well as 24 gauge galvalume (steel).
Some colors are available in 0.050″ and 0.063″ aluminum as well as 22 gauge galvalume.
Material available in sheet or coil format.
Pac Clad Sheets measure 48″ x 120″. No minimum purchase, but fees apply.
Standard coil widths are 20″ and 24″. Coils can be cut to any custom with from 48″ and under. Fees apply. 2000 sqf minimum purchase.
To learn more about Kynar® PVDF coated materials, please click here.

Downloads / Color Charts

 PDF – PAC CLAD – Kynar Aluminum and Galvalume Steel Color Chart

Color Chart – To obtain a physical color chart or color chips, please visit this link.

Unpainted Stocked Materials

Bonderized Steel

Bonderized Steel

Copper

Copper

Freedom gray

Freedom Gray

Galvalume

Galvalume Plus

Galvanized Steel

Galvanized Steel

Lead coated copper

Lead Coated Copper

Mill finish aluminum

Mill Finish Aluminum

Stainless steel

Stainless Steel

More Information

Bonderized Steel: Also known as Paint Grip. Offered in 26 gauge G90. 24 gauge available as special order.

Copper is commonly stocked in 3′ x 10′ and 4’x10′ sheets, 11.75″, 15″ 18″, 20″, 24″ (16 oz. or 20 oz.) and 36″ coil (16 oz.). 24 oz. and 32 oz. are available in 3′ x 10′ sheets. Our typical stock is 1/8 to 1/4 hard copper, supplied by Aurubis, Hussey and Revere.
We also stock 1″ x 3/16″ x 12′ bar stock. Other sizes as well as 48 oz. copper are available as special order items.

Freedom Gray is commonly stocked in 3′ x 10′ sheets of 16 oz. and 20 oz. Coils are available as a special order item with a 1000 lb. minimum. Freedom gray is a Tin / Zinc coated copper from Revere Copper.

Galvalume Plus is an Acrylic coated metal, also known as Acrylume. K&M utilizes Acrylume E Plus™ supplied by US Steel.

Galvanized Steel: Offered in 26 gauge G90. 24 gauge available as special order.

Lead Coated Copper is commonly stocked in 3′ x 10′ sheets of 16 oz. and 20 oz. Special order items include 3′ x 8′ sheets and 12″, 15″, 18″, 20″ and 24″ coil stock. A minimum of 1000 lbs. is required for a coil order.

Mill finish Aluminum is commonly stocked in 4′ x 10′ sheets of 0.032″ and 0.040″.

Stainless Steel in normally available in 24 and 26 gauge 4′ x 10′ sheets, 304 alloy 2B finish. Other thickness, and finishes such as #4, #8 and 2D available as special order items.

Downloads / Color Charts

Looking for a custom color not listed? Please EMAIL your request with all information including the metal manufacturer for a quote.

Other colors, materials and thickness may be available upon request. Colors displayed for reference only.
Please click here for a full selection of colors and materials offered.

Metal roof installations showcasing standing-seam, batten-seam, and flat-lock panels in copper, painted aluminum, steel, and Galvalume Plus. Use these examples to compare profiles and finishes and gather inspiration for your own project..

The pictures below are courtesy of The Century Slate Roofing Company.

FAQs
Questions Before You Order

Metal Roof & Wall Panel FAQs

Compare profiles, understand panel dimensions and prepare the details needed for your project.

Which standing seam panel system is best for my project?

The best choice depends on roof slope, panel length, material, attachment requirements and installation details. Mechanical lock, snap lock and nail strip close and fasten differently. Compare the specific system requirements and drawings rather than choosing solely by appearance or seam height.

How is standing seam different from exposed-fastener roofing?

Standing-seam systems generally conceal the panel attachment within the seams or beneath the adjacent panel. Exposed-fastener systems typically attach through the panel face. These arrangements have different detailing and maintenance needs. Concealed attachment does not eliminate the need to weatherproof roof edges, penetrations and other connections.

What is the difference between single-lock and double-lock seams?

They are different seam-closing configurations for a mechanical-lock panel. The first fold forms the single lock; an additional fold produces the double lock. Use the configuration specified for the roof assembly, material and conditions. Do not substitute one for the other based only on appearance.

Is snap lock easier to install than mechanical lock?

Snap-lock panels avoid the separate mechanical seam-closing operation along the panel joints, which can reduce that part of the installation work. Layout, clips, flashing, cutting and roof details still require appropriate skills. A simpler seam does not make every roof suitable for a DIY installation.

How does nail strip differ from clip-attached snap lock?

Nail-strip panels have a concealed fastening flange formed into the edge. Clip-attached snap-lock panels use separate clips. Both have snap-together seams, but their attachment and movement provisions differ. Follow the chosen system’s fastening and length requirements; thermal movement matters even on shorter panels.

Can K&M make curved or tapered roof panels?

K&M can review curved mechanical-lock panels and custom tapered-panel requests. Availability depends on the profile, material, dimensions and required geometry. Send a drawing with the radius or taper and panel lengths. The standard snap-lock profile described here is intended for straight runs, not curved roof surfaces.

Can flat-lock panels be used on roofs and walls?

Yes, with the appropriate assembly and material. K&M’s flat-roof flat-lock applications require soldered seams and a suitable solderable metal; pre-tinning of edges is available. Painted aluminum and steel can be considered for suitable wall applications, where the attachment, backing and water-management details must also be specified.

What is the minimum slope for metal roofing?

There is no single minimum that applies to every metal panel. Confirm the requirement for the exact profile, seam configuration and complete roof assembly. Seam height alone is not enough to determine suitability. Include the roof slope with your request, especially for low-slope work or roofs with end laps.

What is oil canning, and can ribs prevent it?

Oil canning is visible waviness in a panel’s flat areas. Lighting, viewing angle, width, thickness, handling and installation can affect its appearance. Ribs or striations may help reduce its visibility, but do not guarantee that it will be absent. Discuss appearance expectations before ordering.

What is the difference between coil width and finished panel coverage?

Coil width is the width of the flat material before forming. Some of that width becomes the seams or fastening flange. Finished coverage is the width used for panel layout. For example, the listed 1-inch mechanical-lock profile uses about 3 inches in forming, so 20-inch stock provides about 17 inches of coverage.

Which metals and finishes are available?

Options vary by profile and may include copper, zinc, aluminum, steel and coated copper materials. Kynar refers to a coating resin brand, not the underlying metal. Specify the base metal, thickness and finish, and confirm availability for the panel you need. Coastal exposure and softer metals require particular attention to system suitability.

How long can the panels be?

The Mechanical Lock and Snap Lock online listings specify 3- to 20-foot panels for shipping and lengths up to 40 feet for pickup. Custom profiles and special arrangements must be reviewed separately. Confirm the length, transport and unloading requirements before placing the order.

Are panels sold by the piece, square foot or lineal foot?

The Mechanical Lock and Snap Lock online listings use lineal feet and specify a 100-lineal-foot minimum. Provide the quantity and length of each panel, then add those lengths for the total. Other profiles or custom work may be quoted differently. Installed area also depends on finished coverage width.

What accessories do I need with the panels?

The project may require compatible clips or fasteners, underlayment, closures, eave and rake trim, ridge caps, valley flashing, wall flashing and penetration details. Mechanical seaming or soldering may require additional tools. Coordinate these items with the specified assembly rather than assuming the panels alone form a complete roof.

Are UL or ASTM documents available?

Contact K&M with the specific standard and project requirements. Available documents must be checked against the actual profile, material, thickness, coverage, substrate and attachment. A reference to a test standard does not mean every panel configuration has the same tested performance or approval.

What should I send for a panel quote?

Send the profile and seam height, finished width, material and finish, quantities and cut lengths, roof slope or wall application, and any required drawings or test criteria. Include the delivery location or pickup preference and requested schedule. Provide dimensions for curved, tapered and flat-lock work.

Are metal panels in stock and ready to ship?

K&M panels are made to order. Preparation time depends on the material, profile, quantity, fabrication requirements and production schedule. Confirm the estimated timing for your order and allow additional time for transit. Shipping availability depends on panel size and destination.